DURAN® Measuring and Mixing Cylinder
Your Location: Main>Consumables>Glassware>DURAN® Measuring and Mixing Cylinder
DURAN® measuring and mixing cylidners
Measuring cylinders are used to receive and at the same time to measure various quantities of liquid.
Mixing cylinders can be used for diluting solutions and mixing several components in a given quantity ratio.
DURAN meauring and mixing cylinders are very resistant to mechanical and thermal loads. The large hexagonal base with 3 knobs on its bottom increase stability and prevent the cylidner rolling away. The cylinders have the same wall thickness over the whole measuring range, ensuring linear scales. They are calibrated to contain(“In”) for a reference temperature of 20C. Accuracy limits for measuring and mixing cylidners are laid down in DIN12680, DIN12685 and ISO4788.
DURAN® Measuring cylinders are available in two different accuracy classes – class “A” with main ring points graduation and class “B” with line graduation. For additional differentiation, the measuring cylinders with accuracy class ”A” have a blue graduation whereas the “B” class measuring cylinders a white graduation. The batch certificates for the mixing cylinders are also available to download online.
DURAN® Measuring Cylinder with hexagonal base, class A
blue scale, ring graduations, with batch certificate and certificate of conformity
The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Measuring cylinder accuracy limits conform to DIN and ISO standards. The batch certificates for the mixing cylinders are also available to download online.
Typical applications: holding and simultaneous measurement of varying liquid amounts.
Cat. No. | Capacity (ml) |
d(OD) (mm) |
h (mm) |
Accuracy limits (ml) |
Graduation (ml) |
Pack Unit |
213900701 | 5 | 12 | 112 | 0.05 | 0.1 | 2 |
213900804 | 10 | 14 | 137 | 0.1 | 0.2 | 2 |
213901406 | 25 | 21 | 167 | 0.25 | 0.5 | 2 |
213901706 | 50 | 25 | 196 | 0.5 | 1 | 2 |
213902402 | 100 | 29 | 256 | 0.5 | 1 | 2 |
213903604 | 250 | 39 | 331 | 1 | 2 | 2 |
213904403 | 500 | 53 | 360 | 2.5 | 5 | 2 |
213905408 | 1000 | 65 | 460 | 5 | 10 | 1 |
213906301 | 2000 | 85 | 500 | 10 | 20 | 1 |
DURAN® Measuring Cylinder with hexagonal base, class B
white scale, with graduation
The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Measuring cylinder accuracy limits conform to DIN and ISO standards (class B).
Typical applications: holding and simultaneous measurement of varying liquid amounts.
Cat. No. | Capacity (ml) |
d(OD) (mm) |
h (mm) |
Accuracy limits (ml) |
Graduation (ml) |
Pack Unit |
213960707 | 5 | 12 | 112 | 0.1 | 0.1 | 2 |
213960801 | 10 | 14 | 137 | 0.2 | 0.2 | 2 |
213961403 | 25 | 21 | 167 | 0.5 | 0.5 | 2 |
213961703 | 50 | 25 | 196 | 1 | 1 | 2 |
213962408 | 100 | 29 | 256 | 1 | 1 | 2 |
213963601 | 250 | 39 | 331 | 2 | 2 | 2 |
213964409 | 500 | 53 | 360 | 5 | 5 | 2 |
213965405 | 1000 | 65 | 460 | 10 | 10 | 1 |
213966307 | 2000 | 85 | 500 | 20 | 20 | 1 |
DURAN® Mixing Cylinder with hexagonal base, class A
blue scale, ring graduations, with standard ground joint and ergonomic polyethylene stopper, with batch certificate and certificate of conformity
The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Mixing cylinder accuracy limits conform to DIN and ISO standards. The batch certificates for the mixing cylinders are also available to download online.
Typical applications: diluting solutions, mixing several components with specified proportions.
Cat. No. | Capacity (ml) |
d(OD) (mm) |
h (mm) |
Stopper size |
Accuracy limits (ml) |
Graduation (ml) |
Pack Unit |
246180856 | 10 | 14 | 156 | 10/19 | 0.1 | 0.2 | 2 |
246181458 | 25 | 21 | 190 | 14/23 | 0.25 | 0.5 | 2 |
246181758 | 50 | 25 | 222 | 19/26 | 0.5 | 1 | 2 |
246182454 | 100 | 29 | 287 | 24/29 | 0.5 | 1 | 2 |
246183656 | 250 | 39 | 363 | 29/32 | 1 | 2 | 2 |
246184455 | 500 | 53 | 395 | 34/35 | 2.5 | 5 | 2 |
246185451 | 1000 | 65 | 500 | 45/40 | 5 | 10 | 1 |
246186353 | 2000 | 85 | 540 | 45/40 | 10 | 20 | 1 |
DURAN® Mixing Cylinder with hexagonal base, class B
white scale, with graduation, standard ground joint and polypropylene octagonal stopper
The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Mixing cylinder accuracy limits conform to DIN and ISO standards.
Typical applications: diluting solutions, mixing several components with specified proportions.
Cat. No. | Capacity (ml) |
d(OD) (mm) |
h (mm) |
Stopper size |
Accuracy limits (ml) |
Graduation (ml) |
Pack Unit |
216180801 | 10 | 14 | 156 | 10/19 | 0.2 | 0.2 | 2 |
216181403 | 25 | 21 | 190 | 14/23 | 0.5 | 0.5 | 2 |
216181703 | 50 | 25 | 222 | 19/26 | 1 | 1 | 2 |
216182408 | 100 | 29 | 287 | 24/29 | 1 | 1 | 2 |
216183601 | 250 | 39 | 363 | 29/32 | 2 | 2 | 2 |
216184409 | 500 | 53 | 395 | 34/35 | 5 | 5 | 2 |
216185405 | 1000 | 65 | 500 | 45/40 | 10 | 10 | 1 |
216186307 | 2000 | 85 | 540 | 45/40 | 20 | 20 | 1 |
DURAN® Measuring Cylinder with hexagonal base, class B, graduated low form
white scale, with graduation
The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Measuring cylinder accuracy limits conform to DIN and ISO standards (class B).
Typical applications: holding and simultaneous measurement of varying liquid amounts.
Cat. No. | Capacity (ml) |
d(OD) (mm) |
h (mm) |
Accuracy limits (ml) |
Graduation (ml) |
Pack Unit |
213950809 | 10 | 21 | 90 | 0.2 | 1 | 2 |
213951402 | 25 | 25 | 115 | 0.5 | 1 | 2 |
213951702 | 50 | 29 | 145 | 1 | 2 | 2 |
213952407 | 100 | 39 | 165 | 1 | 2 | 2 |
213953609 | 250 | 54 | 195 | 2 | 5 | 2 |
213954408 | 500 | 65 | 250 | 5 | 10 | 2 |
213955404 | 1000 | 85 | 285 | 10 | 20 | 1 |
213956306 | 2000 | 105 | 340 | 20 | 50 | 1 |
DURAN® SUPER DUTY Measuring Cylinder
low form, class B, with graduation and hexagonal base
The DURAN® SUPER DUTY products are characterized by a higher mechanical strength achieved by reinforcing the rim. As a result of this modification, the impact strength is improved, and the risk of accidental breakage is significantly reduced.
Application note: To avoid breakages due to thermal stress, uniform and slow heating of SUPER DUTY products is recommended.
Cat. No. | Capacity (ml) |
d(OD) (mm) |
h (mm) |
Accuracy limits (ml) |
Graduation (ml) |
Pack Unit |
213942406 | 100 | 39 | 168 | 1 | 2 | 2 |
213943608 | 250 | 54 | 205 | 2 | 5 | 2 |
213944407 | 500 | 66 | 253 | 5 | 10 | 2 |
213945403 | 1000 | 85 | 290 | 10 | 20 | 2 |