DURAN® Measuring and Mixing Cylinder


Your Location: Main>Consumables>Glassware>DURAN® Measuring and Mixing Cylinder

DURAN® measuring and mixing cylidners

Measuring cylinders are used to receive and at the same time to measure various quantities of liquid.

Mixing cylinders can be used for diluting solutions and mixing several components in a given quantity ratio.

DURAN meauring and mixing cylinders are very resistant to mechanical and thermal loads. The large hexagonal base with 3 knobs on its bottom increase stability and prevent the cylidner rolling away. The cylinders have the same wall thickness over the whole measuring range, ensuring linear scales. They are calibrated to contain(“In”) for a reference temperature of 20C. Accuracy limits for measuring and mixing cylidners are laid down in DIN12680, DIN12685 and ISO4788.

DURAN® Measuring cylinders are available in two different accuracy classes – class “A” with main ring points graduation and class “B” with line graduation. For additional differentiation, the measuring cylinders with accuracy class ”A” have a blue graduation whereas the “B” class measuring cylinders a white graduation. The batch certificates for the mixing cylinders are also available to download online.

DURAN® Measuring Cylinder with hexagonal base, class A

blue scale, ring graduations, with batch certificate and certificate of conformity

The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Measuring cylinder accuracy limits conform to DIN and ISO standards. The batch certificates for the mixing cylinders are also available to download online.

Typical applications: holding and simultaneous measurement of varying liquid amounts.

Cat. No. Capacity
(ml)
d(OD)
(mm)
h
(mm)
Accuracy limits
(ml)
Graduation
(ml)
Pack
Unit
213900701 5 12 112 0.05 0.1 2
213900804 10 14 137 0.1 0.2 2
213901406 25 21 167 0.25 0.5 2
213901706 50 25 196 0.5 1 2
213902402 100 29 256 0.5 1 2
213903604 250 39 331 1 2 2
213904403 500 53 360 2.5 5 2
213905408 1000 65 460 5 10 1
213906301 2000 85 500 10 20 1

DURAN® Measuring Cylinder with hexagonal base, class B

white scale, with graduation

The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Measuring cylinder accuracy limits conform to DIN and ISO standards (class B).

Typical applications: holding and simultaneous measurement of varying liquid amounts.

Cat. No. Capacity
(ml)
d(OD)
(mm)
h
(mm)
Accuracy limits
(ml)
Graduation
(ml)
Pack
Unit
213960707 5 12 112 0.1 0.1 2
213960801 10 14 137 0.2 0.2 2
213961403 25 21 167 0.5 0.5 2
213961703 50 25 196 1 1 2
213962408 100 29 256 1 1 2
213963601 250 39 331 2 2 2
213964409 500 53 360 5 5 2
213965405 1000 65 460 10 10 1
213966307 2000 85 500 20 20 1

DURAN® Mixing Cylinder with hexagonal base, class A

blue scale, ring graduations, with standard ground joint and ergonomic polyethylene stopper, with batch certificate and certificate of conformity

The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Mixing cylinder accuracy limits conform to DIN and ISO standards. The batch certificates for the mixing cylinders are also available to download online.

Typical applications: diluting solutions, mixing several components with specified proportions.

Cat. No. Capacity
(ml)
d(OD)
(mm)
h
(mm)
Stopper
size
Accuracy limits
(ml)
Graduation
(ml)
Pack
Unit
246180856 10 14 156 10/19 0.1 0.2 2
246181458 25 21 190 14/23 0.25 0.5 2
246181758 50 25 222 19/26 0.5 1 2
246182454 100 29 287 24/29 0.5 1 2
246183656 250 39 363 29/32 1 2 2
246184455 500 53 395 34/35 2.5 5 2
246185451 1000 65 500 45/40 5 10 1
246186353 2000 85 540 45/40 10 20 1

DURAN® Mixing Cylinder with hexagonal base, class B

white scale, with graduation, standard ground joint and polypropylene octagonal stopper

The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Mixing cylinder accuracy limits conform to DIN and ISO standards.

Typical applications: diluting solutions, mixing several components with specified proportions.

Cat. No. Capacity
(ml)
d(OD)
(mm)
h
(mm)
Stopper
size
Accuracy limits
(ml)
Graduation
(ml)
Pack
Unit
216180801 10 14 156 10/19 0.2 0.2 2
216181403 25 21 190 14/23 0.5 0.5 2
216181703 50 25 222 19/26 1 1 2
216182408 100 29 287 24/29 1 1 2
216183601 250 39 363 29/32 2 2 2
216184409 500 53 395 34/35 5 5 2
216185405 1000 65 500 45/40 10 10 1
216186307 2000 85 540 45/40 20 20 1

DURAN® Measuring Cylinder with hexagonal base, class B, graduated low form

white scale, with graduation

The large hexagonal base prevents the cylinder from rolling. The base is equipped with three knobs which increase its stability. The cylinders have uniform wall thickness over the entire measurement range, so wedge errors are avoided. Calibration is based on the poured in volume (“In”) at a + 20 °C reference temperature. Measuring cylinder accuracy limits conform to DIN and ISO standards (class B).

Typical applications: holding and simultaneous measurement of varying liquid amounts.

Cat. No. Capacity
(ml)
d(OD)
(mm)
h
(mm)
Accuracy limits
(ml)
Graduation
(ml)
Pack
Unit
213950809 10 21 90 0.2 1 2
213951402 25 25 115 0.5 1 2
213951702 50 29 145 1 2 2
213952407 100 39 165 1 2 2
213953609 250 54 195 2 5 2
213954408 500 65 250 5 10 2
213955404 1000 85 285 10 20 1
213956306 2000 105 340 20 50 1

DURAN® SUPER DUTY Measuring Cylinder

low form, class B, with graduation and hexagonal base

The DURAN® SUPER DUTY products are characterized by a higher mechanical strength achieved by reinforcing the rim. As a result of this modification, the impact strength is improved, and the risk of accidental breakage is significantly reduced.

Application note: To avoid breakages due to thermal stress, uniform and slow heating of SUPER DUTY products is recommended.

Cat. No. Capacity
(ml)
d(OD)
(mm)
h
(mm)
Accuracy limits
(ml)
Graduation
(ml)
Pack
Unit
213942406 100 39 168 1 2 2
213943608 250 54 205 2 5 2
213944407 500 66 253 5 10 2
213945403 1000 85 290 10 20 2

Related Products